Field Probes

WP10M Field Probe

1 Hz – 10 MHz
E & H field
Selective & Broadband

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defence (LF)
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413

In accordance with IEC/EN 61786-1.

Datasheet Contact Us

Compatible with:

SMP3

WP50 Field Probe

10 Hz – 3 kHz
E & H field
Broadband

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Induction heating: EN 50519
  • Electric arc or induction smelting
  • Workplace assessment: EN 50499
  • Human exposure assessment: EN 50413
  • Other low frequency applications

In accordance with IEC/EN 61786-1.

Datasheet Contact Us

Compatible with:

SMP3

MonitEM

WP400 Field Probe

1 Hz – 400 kHz
E & H field
Selective & Broadband

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defence (LF)
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413

In accordance with IEC/EN 61786-1.

Datasheet Contact Us

Compatible with:

SMP3

WP400c Field Probe

1 Hz – 400 kHz
E & H field
Selective & Broadband

MAIN APPLICATIONS

  • Automotive
  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defence (LF)
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413

In accordance with IEC/EN 61786-1.
GB 8702-2014 limit included

.

Datasheet Contact Us

Compatible with:

SMP3

WP400-3 Field Probe

1 Hz – 400 kHz
E & H field
Selective & Broadband

MAIN APPLICATIONS

  • Assessment of:
    • Welding equipment: IEC/EN 62822, EN 50505
    • Household appliances: IEC/EN 62233, EN 50366
    • Other electronic/electrical equipment: IEC/EN 62311
  • Research/Labs
  • Other application where small size and spatial resolution is important

In accordance with IEC/EN 61786-1.

Datasheet Contact Us

Compatible with:

SMP3

WPF3 Field Probe

100 kHz – 3 GHz
E field
Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
Datasheet Contact Us

Compatible with:

SMP3

MonitEM

MonitEM-Lab

WPF6 Field Probe

100 kHz – 6 GHz
E field
Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401, EN 50492
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
Datasheet Contact Us

Compatible with:

SMP3

MonitEM

MonitEM-Lab

WPF8 Field Probe

100 kHz – 8 GHz
E field
Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401, EN 50492
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
Datasheet Contact Us

Compatible with:

SMP3

MonitEM

MonitEM-Lab

WPF18 Field Probe

300 kHz – 18 GHz
E field
Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Radar
  • Defence (HF)
Datasheet Contact Us

Compatible with:

SMP3

MonitEM

MonitEM-Lab

WPF40 Field Probe

1 MHz – 40 GHz
E field
Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defence (HF)
Datasheet Contact Us

Compatible with:

SMP3

MonitEM

MonitEM-Lab

WPF60 Field Probe

1 MHz – 60 GHz
E field
Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50600, EN 50601
    • Broadcast:IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defence (HF)
Datasheet Contact Us

Compatible with:

SMP3

MonitEM

MonitEM-Lab

WPH60 Field Probe

300 kHz – 60 MHz
H field
Broadband

MAIN APPLICATIONS

  • Broadcasting: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
Datasheet Contact Us

Compatible with:

SMP3

MonitEM

WPH1000 Field Probe

30 MHz – 1000 MHz
H field
Broadband

MAIN APPLICATIONS

  • Broadcasting: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Defence
Datasheet Contact Us

Compatible with:

SMP3

MonitEM

MonitEM-Lab

WPH-DC Probe

DC – 40 kHz
H Field
Selective & Broadband

APPLICATIONS

  • Medical (MRI: Magnetic Resonance Imaging): IEC 60601-2-33
  • Railway (DC Motors): EN 50500
  • Automotive (Electrical vehicles)
  • Chemical Industry (Electrolysis)
  • Strong Permanent Magnets (Heavy duty magnet lifters)
  • Energy (DC generators)
  • Metrology (Earth static field)
Datasheet Contact Us

Compatible with:

SMP3

WPT Field Probe

Bands: 700-900, 1800-1900, 2100 and 2600
E field
Selective broadband

MAIN APPLICATIONS

  • Assessment of mobile telephony base stations
Datasheet Contact Us

Compatible with:

SMP3

MonitEM