WaveMon RF-60
RF Personal Monitor

ELECTRIC FIELD DETECTION

Isotropic sensors with RMS response

WEIGHTED RESPONSE TO INTERNATIONAL STANDARDS

ICNIRP, European Directive 2013/35/EU, FCC, Safety Code 6 (2015) and NATO

COMPLIANCE WITH ITU-T K.145

INSTANT AND AVERAGE VALUES

Alarms on instant and average values. Configurable

EXPOSIMETER WITH DATALOGGER

Data collecting and Reporting

GPS AND ALTIMETER

Geolocation of measurements

HIGH INTENSITY AUDIBLE, VISIBLE AND VIBRATORY ALARM

With user definable trigger threshold

USB COMMUNICATION PORT

Data downloading, set-up and battery charging

Order Now

WEIGHTED RESPONSE

The WaveMon gives a specific weighted response for each standard. It is not just single model that attempts to follow all standards at once. Such an approach will always result in poorer accuracy. This is a weighted response, designed to follow the limits of the applicable standard, for greater accuracy.

 

The following monitors are now available:

  • WaveMon RF-60 ICN → ICNIRP version
  • WaveMon RF-60 EUD → European Directive 2013/35/EU version
  • WaveMon RF-60 FCC → FCC version
  • WaveMon RF-60 SC6 → Safety Code 6 (2015) version
  • WaveMon RF-60 NATO → NATO version

If you need a personal radio frequency monitor that specifically follows some other standard, please let us know.

DATALOGGER

The WaveMon is a radio frequency exposimeter that have a datalogger for continuous data recording.

Communication with the device is through a USB port that allows you to parametrise the device and download the recorded data. This makes it easy to create reports and allows you to keep a record of your exposure data for your safety.

CONVENIENCE AND SECURITY

We have created an accessory that allows you to attach the personal monitor to your harness, arm or belt and so take it in hand to hold it near a radiation source and then put it back in place easily.

You can also secure it with a small carabiner so that it won’t be dropped.

BATTERIES

The device is small and lightweight and works with AA batteries that can be recharged via the USB port. It can also use standard AA batteries, so that they can always be easily replaced.

Easy, isn’t it? Because we want you always to be protected.

GPS AND ALTIMETER

The WaveMon is the only personal monitor equipped with a GPS and Altimeter for geolocation of measurements.

As an example, in a high voltage tower, the GPS will provide the geographical position of the tower and the Altimeter the relative height from the ground.

ALARMS ON INSTANT AND AVERAGE VALUES

The WaveMon is the only personal RF monitor that can give alarms for average value and instantaneous value at the same time.

Remember that internationally established exposure limits are specified as values averaged over a given time (e.g. 6 or 30 minutes). Some important examples include the limits established under ICNIRP, FCC, Safety Code 6, European Directive 2013/35/EU, etc.

USER-CONFIGURABLE ALARMS

Over-exposure alarms can be configured from a PC with all their parameters. Two different alarms can be programmed and personalised separately. The following basic parameters can be personalised:

  • Value type (generated by instantaneous or average value)
  • Alarm level (% of limit)
  • Type of alarm (sound, vibration or both)

RF ABSORTION

When the personal monitor is worn on the body, which is how it is most often used, reflections of electromagnetic fields from the body itself can affect the measurement and compromise its accuracy.

The holder for the WaveMon includes an RF absorbent material to reduce that effect. When the device is in the holder, next to the body, the absorbent material is placed strategically between the sensor and the body, but when it is used away from the body, outside the holder, that material is not present and the WaveMon gives an undisturbed isotropic behaviour.

LOW FREQUENCY IMMUNITY

Experience shows that personal RF monitors with poor immunity to low frequencies give false alarms near high-voltage lines or other types of powerful electric equipment.

The WaveMon is the personal monitor with the best immunity and it can work in electric field intensity conditions of up to 30 kV/m at 50/60 Hz without giving false readings of non-existent RF levels. That is better, for example, than the occupational exposure limit under ICNIRP: 20 kV/m.

MAIN CHARACTERISTICS OF THE WAVEMON

  • Conforms to international electromagnetic field safety standards

  • E-field measurements up to 60 GHz

  • Isotropic sensors

  • RMS detection

  • Weighted response chosen from among ICNIRP, European Directive 2013/35/EU, FCC, Safety Code 6 (2015) and NATO, for direct comparison with the standard limit

  • Instantaneous and average values, according to international standards

  • High immunity at a 50/60 Hz: 30 kV/m

  • User-configurable alarms

  • High intensity audible, visible and vibration alarms

  • Customisable alarm threshold

  • Optional GPS and altimeter

  • Datalogger to report and record data

  • RF absorption to reduce reflections from the user’s body

  • USB for PC connection to parameterise and download data

  • Small and lightweight

  • Powered by 2 standard disposable or rechargeable (via USB port) batteries

  • Autonomy over 200 hours

DOWNLOADS

Datasheet

ITU-T K.145